首页 >MT8941B>规格书列表

型号下载 订购功能描述制造商 上传企业LOGO

MT8941B

CMOS ST-BUS??FAMILY Advanced T1/CEPT Digital Trunk PLL

Description The MT8941B is a dual digital phase-locked loop providing the timing and synchronization signals for the T1 or CEPT transmission links and the ST-BUS. The first PLL provides the T1 clock (1.544 MHz) synchronized to the input frame pulse at 8 kHz. The timing signals for the CEPT tran

文件:131.21 Kbytes 页数:22 Pages

Mitel

MT8941BE

CMOS ST-BUS??FAMILY Advanced T1/CEPT Digital Trunk PLL

Description The MT8941B is a dual digital phase-locked loop providing the timing and synchronization signals for the T1 or CEPT transmission links and the ST-BUS. The first PLL provides the T1 clock (1.544 MHz) synchronized to the input frame pulse at 8 kHz. The timing signals for the CEPT tran

文件:131.21 Kbytes 页数:22 Pages

Mitel

MT8941BE

Advanced T1/CEPT Digital Trunk PLL

Description The MT8941B is a dual digital phase-locked loop providing the timing and synchronization signals for the T1 or CEPT transmission links and the ST-BUS. The first PLL provides the T1 clock (1.544 MHz) synchronized to the input frame pulse at 8 kHz. The timing signals for the CEPT tran

文件:491.07 Kbytes 页数:27 Pages

ZARLINK

Zarlink Semiconductor Inc

MT8941BP

CMOS ST-BUS??FAMILY Advanced T1/CEPT Digital Trunk PLL

Description The MT8941B is a dual digital phase-locked loop providing the timing and synchronization signals for the T1 or CEPT transmission links and the ST-BUS. The first PLL provides the T1 clock (1.544 MHz) synchronized to the input frame pulse at 8 kHz. The timing signals for the CEPT tran

文件:131.21 Kbytes 页数:22 Pages

Mitel

MT8941BP

Advanced T1/CEPT Digital Trunk PLL

Description The MT8941B is a dual digital phase-locked loop providing the timing and synchronization signals for the T1 or CEPT transmission links and the ST-BUS. The first PLL provides the T1 clock (1.544 MHz) synchronized to the input frame pulse at 8 kHz. The timing signals for the CEPT tran

文件:491.07 Kbytes 页数:27 Pages

ZARLINK

Zarlink Semiconductor Inc

MT8941BP1

Advanced T1/CEPT Digital Trunk PLL

Description The MT8941B is a dual digital phase-locked loop providing the timing and synchronization signals for the T1 or CEPT transmission links and the ST-BUS. The first PLL provides the T1 clock (1.544 MHz) synchronized to the input frame pulse at 8 kHz. The timing signals for the CEPT tran

文件:491.07 Kbytes 页数:27 Pages

ZARLINK

Zarlink Semiconductor Inc

MT8941BPR

Advanced T1/CEPT Digital Trunk PLL

Description The MT8941B is a dual digital phase-locked loop providing the timing and synchronization signals for the T1 or CEPT transmission links and the ST-BUS. The first PLL provides the T1 clock (1.544 MHz) synchronized to the input frame pulse at 8 kHz. The timing signals for the CEPT tran

文件:491.07 Kbytes 页数:27 Pages

ZARLINK

Zarlink Semiconductor Inc

MT8941BPR1

Advanced T1/CEPT Digital Trunk PLL

Description The MT8941B is a dual digital phase-locked loop providing the timing and synchronization signals for the T1 or CEPT transmission links and the ST-BUS. The first PLL provides the T1 clock (1.544 MHz) synchronized to the input frame pulse at 8 kHz. The timing signals for the CEPT tran

文件:491.07 Kbytes 页数:27 Pages

ZARLINK

Zarlink Semiconductor Inc

MT8941B

CMOS ST-BUS™ FAMILY Advanced T1/CEPT Digital Trunk PLL

Description\nThe MT8941B is a dual digital phase-locked loop providing the timing and synchronization signals for the T1 or CEPT transmission links and the ST-BUS. The first PLL provides the T1 clock (1.544 MHz) synchronized to the input frame pulse at 8 kHz. The timing signals for the CEPT transmis • Provides T1 clock at 1.544 MHz locked to an 8 kHz reference clock (frame pulse)\n• Provides CEPT clock at 2.048 MHz and ST-BUS clock and timing signals locked to an internal or\nexternal 8 kHz reference clock\n• Typical inherent output jitter (unfiltered)= 0.07 UI peak-to-peak\n• Typical jitter at;

Mitel

MT8941B

Advanced T1/CEPT Digital Trunk PLL

Description\nThe MT8941B is a dual digital phase-locked loop providing the timing and synchronization signals for the T1 or CEPT transmission links and the ST-BUS. The first PLL provides the T1 clock (1.544 MHz) synchronized to the input frame pulse at 8 kHz. The timing signals for the CEPT transmis • Provides T1 clock at 1.544 MHz locked to an 8kHz reference clock (frame pulse)\n• Provides CEPT clock at 2.048 MHz and ST-BUS clock and timing signals locked to an internal or external 8 kHz reference clock\n• Typical inherent output jitter (unfiltered)= 0.07 UI peak-to-peak\n•Typical jitter atten;

Microchip

微芯科技

详细参数

  • 型号:

    MT8941B

  • 制造商:

    MITEL

  • 制造商全称:

    Mitel Networks Corporation

  • 功能描述:

    CMOS ST-BUS⑩ FAMILY Advanced T1/CEPT Digital Trunk PLL

供应商型号品牌批号封装库存备注价格
MITEL
24+
PLCC
5000
公司存货
询价
MITEL
23+
PLCC
7000
绝对全新原装!100%保质量特价!请放心订购!
询价
MT
PLCC
28
询价
MITEL
25+
DIP
2037
⊙⊙新加坡大量现货库存,深圳常备现货!欢迎查询!⊙
询价
MITEL
25+
PLCC
14
百分百原装正品 真实公司现货库存 本公司只做原装 可
询价
MITEL
25+
SOP16
18000
原厂直接发货进口原装
询价
MITEL
2016+
PLCC-28
8880
只做原装,假一罚十,公司可开17%增值税发票!
询价
MITEL
24+
DIP
45
原装现货假一罚十
询价
MITEL
24+
DIP
5632
公司原厂原装现货假一罚十!特价出售!强势库存!
询价
ZARLINK
24+
PLCC28
5000
全现原装公司现货
询价
更多MT8941B供应商 更新时间2025-12-11 16:01:00