首页>商情资讯>企业新闻

B0512LS-1W原装现货出售

2023-2-23 15:30:00
  • "Hi Pot Test","Flash Tested","Withstand Voltage","Dielectric Withstand Voltage"&”Isolation Test Voltage" are all terms that relate to the same thing, a test voltage. Applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.

"Hi Pot Test","Flash Tested","Withstand Voltage","Dielectric Withstand Voltage"&”Isolation Test Voltage" are all terms that relate to the same thing, a test voltage. Applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. Professional Power Module B_LS series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1KVDC for 1 second.A question commonly asked is,"What is the continuous voltage that can be applied across the part in normal operation?" For a part holding no specific agency approvals, such as the B series ,both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC.The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The partcould be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier, but then the circuitry on both sides of the barrier mustbe regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-acssible circuitry according tosafety standard requirements. REPEATED HIGH-VOLTAGE ISOLATION TESTING It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials.Construction and environment. The B_LS series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. Whileparts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typicallypolyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. Wetherefore strongly advise against repeated high voltage isolation testing. but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage.This consideration equally applies to agency recognized parts for better than functional isolation where the wire enamel insulation is always supplemented by a furtherinsulation system of physical spacing or barriers. 专业代理,全新到货,大量现货欢迎询问!!!

质优价廉,品质保证!

批号:13+

专业代理全线产品,优势的进货渠道,专业的销售团队,一手货源,全国最低价供应!

为您提供专业、快捷、可靠的产品

深圳德田科技有限公司

Shenzhen Spring Technology Co.,Ltd

地址:深圳市福田区振华路122号海外装饰大厦A座201B室

Shenzhen futian district zhenhua road 122 overseas decoration building, room 211, block A, 518031

李先生

电话(Tel):(+86-755) 8350 5153

传真(Fax):(+86-755) 8350 2530

邮箱: info@dt-ic.com

网址:www.dt-ic.com