首页>OPT4001-Q1_V01>规格书详情
OPT4001-Q1_V01中文资料德州仪器数据手册PDF规格书
OPT4001-Q1_V01规格书详情
1 Features
• AEC-Q100 qualified for automotive applications:
– Temperature grade 2: –40°C to +105°C, TA
• Functional Safety-Capable
– Documentation available to aid functional safety
system design
• High-precision, high-speed light-to-digital
conversion over high-speed I2C interface
• Precision optical filtering closely matches human
eye with excellent near infrared (IR) rejection
• Semi-logarithmic output:
– Nine binary logarithmic full-scale light range
– Highly linear response within each range
• Built-in automatic full-scale light range selection
logic, which switches measurement range based
on input light condition for best possible resolution
at all times
• 28 bits of effective dynamic range:
– 400 μlux to 107 klux
• 12 configurable conversion times:
– 600 μs to 800 ms for high-speed and highprecision
applications
• External pin interrupt for hardware-synchronized
trigger and interrupts
• Error correction code features for improved
reliability in automotive use cases
• Internal FIFO for output registers with I2C burst
readout
• Low operating current: 30 μA
• Ultra-low power standby: 2 μA
• Operating temperature range: –40°C to +105°C
• Wide power-supply range: 1.6 V to 3.6 V
• 5.5-V tolerant I/O pins
• Selectable I2C address
• Small-form factor: 2 mm × 2 mm × 0.65 mm
2 Applications
• Automotive interior and exterior lighting
• Infotainment and cluster
• Electrochromatic and smart mirrors
• Wiper modules
• Head-up display systems
• Automotive camera systems
3 Description
The OPT4001-Q1 is a light-to-digital sensor (single
chip lux meter) that measures the intensity of visible
light. To measure accurate light intensity, a specially
engineered filter on the device tightly matches the
photopic response of the human eye and rejects the
near-infrared component from common light sources.
The output of OPT4001-Q1 is semi-logarithmic with
nine binary logarithmic full-scale light ranges along
with a highly linear response within each range,
bringing capability to measure from 400 μlux to 107
klux. This capability allows light sensor to have 28-bit
effective dynamic range. The built-in automatic range
selection logic dynamically adjusts the device gain
settings based on the light level, providing the best
possible resolution in all conditions without user input.
供应商 | 型号 | 品牌 | 批号 | 封装 | 库存 | 备注 | 价格 |
---|---|---|---|---|---|---|---|
Phoenix/菲尼克斯 |
23/24+ |
2967989 |
9249 |
优势特价 原装正品 全产品线技术支持 |
询价 | ||
SEMITEC |
22+ |
SEMITEC |
30000 |
十七年VIP会员,诚信经营,一手货源,原装正品可零售! |
询价 | ||
TI(德州仪器) |
2021+ |
COG-78 |
499 |
询价 | |||
TI(德州仪器) |
24+ |
PicoStar4(0.8x1.1) |
7350 |
现货供应,当天可交货!免费送样,原厂技术支持!!! |
询价 | ||
TI/德州仪器 |
25+ |
XCEPT |
860000 |
明嘉莱只做原装正品现货 |
询价 | ||
TI(德州仪器) |
2024+ |
N/A |
500000 |
诚信服务,绝对原装原盘 |
询价 | ||
OPTREX |
24+ |
NA/ |
4084 |
原厂直销,现货供应,账期支持! |
询价 | ||
TI/德州仪器 |
22+ |
UNKNOWN |
12245 |
现货,原厂原装假一罚十! |
询价 | ||
SEMITEC |
24+ |
NA |
50000 |
只做原装正品现货 欢迎来电查询15919825718 |
询价 | ||
SEMITEC |
22+ |
SEMITEC |
28000 |
原装现货只有原装.假一罚十 |
询价 |