首页>TLC69660QPWPRQ1>规格书详情
TLC69660QPWPRQ1中文资料德州仪器数据手册PDF规格书
TLC69660QPWPRQ1规格书详情
1 Features
• AEC-Q100 qualified for automotive applications:
– Device temperature grade 1: –40°C to +125°C,
TA
– Device HBM ESD classification level 2
– Device CDM ESD classification level C4B
• Functional Safety-Capable:
– Documentation available to aid functional safety
system design
• Full array local dimming topology:
– Support up to 1024 devices cascaded
• Operating voltage VCC range: 3 V to 5.5 V
• Flexible P-MOSFET driving options:
– Maximum channel current / voltage:
• 30 mA / 20 V: TLC69600-Q1
• 60 mA / 20 V: TLC69610-Q1
• 30 mA / 50 V: TLC69650-Q1
• 60 mA / 50 V: TLC69660-Q1
– Global 8-bit Maximum Current (MC) setting
– Individual 8-bit Channel Current (CC) setting
• High speed daisy chain interface:
– I/O voltage compatible with: 1.8 V / 3.3 V
– Data transfer rate: up to 20 MHz
• EMI enhancement:
– Programmable interface driving capability
• Diagnostics:
– Device thermal shutdown detection
– Report interface option:
• UART and interrupt pin (INT)
• Two-wire output: CLK_O and SOUT
2 Applications
• LCD local dimming backlight:
– Automotive Central Information Display
– Automotive Cluster Display
– Automotive Head-up Display
3 Description
TLC696x0-Q1 is a scan MOSFET controller
compatible with current-sink driver TLC696x2/4/8-Q1
to achieve 2/4/8 time-multiplexing control. Each
device integrates with 16 constant current sinks for
up to 8 scan MOSFETs control. The device equips
with ghost-cancellation function to eliminate upside
ghosting.
To optimize system efficiency, the device is equipped
with adaptive headroom voltage control scheme to
directly control DC/DC. Only the FB pin from last
device in serial chain should be connected to DC/DC
to achieve simplified system layout. The device also
integrates minimum brightness update latency, black
insertion and VRR features to improve display quality.
TLC696x0-Q1 has three error flags: LED open
detection (LOD), LED short detection (LSD) and
thermal shutdown detection (TSD) for diagnostic. The
device implements two options for readback including
UART/INT and SOUT/CLK_O which is programmable
by register.