General description

The PCA9541A is a 2-to-1 I2C-bus master selector designed for high reliability dual

master I2C-bus applications where system operation is required, even when one master

fails or the controller card is removed for maintenance. The two masters (for example,

primary and back-up) are located on separate I2C-buses that connect to the same

downstream I2C-bus slave devices. I2C-bus commands are sent by either I2C-bus master and are used to select one master at a time. Either master at any time can gain control of the slave devices if the other master is disabled or removed from the system. The failed master is isolated from the system and does not affect communication between the on-line master and the slave devices on the downstream I2C-bus.

Two versions are offered for different architectures. PCA9541A/01 with channel 0

selected at start-up, and PCA9541A/03 with no channel selected after start-up.

The interrupt outputs are used to provide an indication of which master has control of the bus. One interrupt input (INT_IN) collects downstream information and propagates it to the 2 upstream I2C-buses (INT0 and INT1) if enabled. INT0 and INT1 are also used to let the previous bus master know that it is not in control of the bus anymore and to indicate the completion of the bus recovery/initialization sequence. If the masking option is set, those interrupts can be disabled and do not generate an interrupt.

A bus recovery/initialization if enabled sends nine clock pulses, a not acknowledge, and a

STOP condition in order to set the downstream I2C-bus devices to an initialized state

before actually switching the channel to the selected master. An interrupt is sent to the upstream channel when the recovery/initialization procedure is completed. An internal bus sensor senses the downstream I2C-bus traffic and generates an interrupt if a channel switch occurs during a non-idle bus condition. This function is enabled when

the PCA9541A recovery/initialization is not used. The interrupt signal informs the master

that an external I2C-bus recovery/initialization must be performed. It can be disabled and an interrupt is not generated. The pass gates of the switches are constructed such that the VDD pin can be used to limit the maximum high voltage, which will be passed by the PCA9541A. This allows the use of different bus voltages on each pair, so that 1.8 V, 2.5 V, or 3.3 V devices can communicate with 5 V devices without any additional protection. The PCA9541A does not isolate the capacitive loading on either side of the device, so the designer must take into account all trace and device capacitances on both sides of the device, and pull-up resistors must be used on all channels. External pull-up resistors pull the bus to the desired voltage level for each channel. All I/O pins are 6.0 V tolerant.An active LOW reset input allows the PCA9541A to be initialized. Pulling the RESET pin LOW resets the I2C-bus state machine and configures the device to its default state as does the internal Power-On Reset (POR) function.

Features and benefits

 2-to-1 bidirectional master selector

 I2C-bus interface logic; compatible with SMBus standards

 PCA9541A/01 powers up with Channel 0 selected

 PCA9541A/03 powers up with no channel selected and either master can take control

of the bus

 Active LOW interrupt input

 2 active LOW interrupt outputs

 Active LOW reset input

 4 address pins allowing up to 16 devices on the I2C-bus

 Channel selection via I2C-bus

 Bus initialization/recovery function

 Bus traffic sensor

 Low Ron switches

 Allows voltage level translation between 1.8 V, 2.5 V, 3.3 V and 5 V buses

 No glitch on power-up

 Supports hot insertion

 Software identical for both masters

 Low standby current

 Operating power supply voltage range of 2.3 V to 5.5 V

 6.0 V tolerant inputs

 0 Hz to 400 kHz clock frequency

 ESD protection exceeds 2000 V HBM per JESD22-A114 and 1000 V CDM per

JESD22-C101

 Latch-up testing is done to JEDEC Standard JESD78 which exceeds 100 mA

 Packages offered: SO16, TSSOP16, HVQFN16

供应商 型号 品牌 批号 封装 库存 备注 价格
恩XP
17+
TSSOP16
6200
100%原装正品现货
询价
恩XP
2016+
TSSOP16
6000
只做原装,假一罚十,公司可开17%增值税发票!
询价
恩XP
2021/2022+
N/A
6000
原厂原装现货订货价格优势终端BOM表可配单提供样品
询价
恩XP
24+
TSSOP-16
15138
询价
恩XP
25+
25000
原厂原包 深圳现货 主打品牌 假一赔百 可开票!
询价
恩XP
24+
TSSOP
10000
全新原装现货库存
询价
恩XP
2023+
16-TSSOP
1425
安罗世纪电子只做原装正品货
询价
恩XP
2022+
原厂原包装
8600
全新原装 支持表配单 中国著名电子元器件独立分销
询价
恩XP
2020+
TSSOP
2526
百分百原装正品 真实公司现货库存 本公司只做原装 可
询价
恩XP
23+
TSSOP-16
20000
询价