首页>DLMU>规格书详情

DLMU中文资料力特数据手册PDF规格书

PDF无图
厂商型号

DLMU

功能描述

Voltage Monitoring Relays

文件大小

255.02 Kbytes

页面数量

2

生产厂商

Littelfuse

中文名称

力特

网址

网址

数据手册

下载地址一下载地址二到原厂下载

更新时间

2025-12-14 23:01:00

人工找货

DLMU价格和库存,欢迎联系客服免费人工找货

DLMU规格书详情

描述 Description

The DLMU Series is a universal voltage, 3-phase voltage

monitor. It continuously measures the voltage of each of the

three phases with microcontroller accuracy and compares the

value to preset trip points. It separately senses phase reversal

and loss; over, under and unbalanced voltages; and over or

under frequency. Protection is assured during periods of large

average voltage fluctuations or when regenerated voltages

are present. The unit trips within 200ms when phase loss

is detected. Adjustable time delays are included to prevent

nuisance tripping and short cycling of sensitive equipment.

The isolated, 10A, SPDT and 2A alarm output relay contacts

trip when a phase voltage exceeds the trip limits for the trip

delay. Nominal line voltage, voltage unbalance, and time

delays are knob adjustable. The phase loss setpoint and the

acceptable frequency range are fixed. Both delta and wye

systems can be monitored; no connection to neutral is required.

Operation

Upon application of line voltage, the output is de-energized

and the restart delay begins. If all the 3-phase voltages are

within the acceptable range, the output energizes at the end

of the restart delay. The microcontroller circuitry automatically

senses the voltage range, and selects the correct operating

frequency (50 or 60Hz). The over and undervoltage trip points

are set automatically. When the measured value of any phase

voltage exceeds the acceptable range limits (lower or upper)

the trip delay begins. At the end of the trip delay the output

relay de-energizes. If the phase voltage returns to an acceptable

value before the trip delay expires, the trip delay is reset and the

output remains energized. Under, over, and unbalanced voltages

plus over or under frequency must be sensed for the complete

trip delay before the unit trips. The unit trips in 200ms when

phase loss or reversal are sensed. The unit will not energize if a

fault is sensed as the line voltage is applied.

Reset: Reset is automatic upon correction of the voltage or

frequency fault or phase sequence.

FEATURES BENEFITS

Proprietary

microcontroller

based circuitry

Constant monitoring to protect against phase loss,

phase reversal, over voltage, under voltage,

unbalance, short cycling and over/under frequency

Universal line

voltage range

Flexibility to work in 200 to 480VAC or 500 to

600VAC applications

DIN rail (35mm) or

surface mounting Installation flexibility

LED indication Provides diagnostics of relay, fault and time

delay status

User adjustable

time delays

Prevents nuisance tripping and short cycling of

sensitive equipment

供应商 型号 品牌 批号 封装 库存 备注 价格
F
24+
NA/
3775
原装现货,当天可交货,原型号开票
询价
SCHURTER
24+
插件
7350
现货供应,当天可交货!免费送样,原厂技术支持!!!
询价
FAIRCHILD/仙童
25+
DIP8
54648
百分百原装现货 实单必成 欢迎询价
询价
FAIRCHILD/仙童
24+
DIP8
990000
明嘉莱只做原装正品现货
询价
OSR
24+
20
询价
三年内
1983
只做原装正品
询价
JRC
24+
PQFP
5645
公司原厂原装现货假一罚十!特价出售!强势库存!
询价
OSRAM
23+
DIP
50000
只做原装正品
询价
ON/安森美
23+
15000
原厂授权一级代理,专业海外优势订货,价格优势、品种
询价
24+
N/A
70000
一级代理-主营优势-实惠价格-不悔选择
询价