首页 >ADS1292I>规格书列表

型号下载 订购功能描述制造商 上传企业LOGO

ADS1292I

Low-Power, 2-Channel, 24-Bit Analog Front-End for Biopotential Measurements

文件:1.52543 Mbytes 页数:69 Pages

TI

德州仪器

ADS1292IPBS

丝印:ADS1292;Package:TQFP(PBS);ADS129x Low-Power, 2-Channel, 24-Bit Analog Front-End for Biopotential Measurements

1 Features 1• Two low-noise PGAs and two high-resolution ADCs (ADS1292 and ADS1292R) • Low power: 335 μW/channel • Input-referred noise: 8 μVPP (150-Hz BW, G = 6) • Input bias current: 200 pA • Data rate: 125 SPS to 8 kSPS • CMRR: 120 dB • Programmable gain: 1, 2, 3, 4, 6, 8, or 12 • Su

文件:2.36085 Mbytes 页数:83 Pages

TI

德州仪器

ADS1292IPBS.A

丝印:ADS1292;Package:TQFP(PBS);ADS129x Low-Power, 2-Channel, 24-Bit Analog Front-End for Biopotential Measurements

1 Features 1• Two low-noise PGAs and two high-resolution ADCs (ADS1292 and ADS1292R) • Low power: 335 μW/channel • Input-referred noise: 8 μVPP (150-Hz BW, G = 6) • Input bias current: 200 pA • Data rate: 125 SPS to 8 kSPS • CMRR: 120 dB • Programmable gain: 1, 2, 3, 4, 6, 8, or 12 • Su

文件:2.36085 Mbytes 页数:83 Pages

TI

德州仪器

ADS1292IPBSR

丝印:ADS1292;Package:TQFP(PBS);ADS129x Low-Power, 2-Channel, 24-Bit Analog Front-End for Biopotential Measurements

1 Features 1• Two low-noise PGAs and two high-resolution ADCs (ADS1292 and ADS1292R) • Low power: 335 μW/channel • Input-referred noise: 8 μVPP (150-Hz BW, G = 6) • Input bias current: 200 pA • Data rate: 125 SPS to 8 kSPS • CMRR: 120 dB • Programmable gain: 1, 2, 3, 4, 6, 8, or 12 • Su

文件:2.36085 Mbytes 页数:83 Pages

TI

德州仪器

ADS1292IPBSR.A

丝印:ADS1292;Package:TQFP(PBS);ADS129x Low-Power, 2-Channel, 24-Bit Analog Front-End for Biopotential Measurements

1 Features 1• Two low-noise PGAs and two high-resolution ADCs (ADS1292 and ADS1292R) • Low power: 335 μW/channel • Input-referred noise: 8 μVPP (150-Hz BW, G = 6) • Input bias current: 200 pA • Data rate: 125 SPS to 8 kSPS • CMRR: 120 dB • Programmable gain: 1, 2, 3, 4, 6, 8, or 12 • Su

文件:2.36085 Mbytes 页数:83 Pages

TI

德州仪器

ADS1292IRSMR

丝印:ADS1292;Package:VQFN(RSM);ADS129x Low-Power, 2-Channel, 24-Bit Analog Front-End for Biopotential Measurements

1 Features 1• Two low-noise PGAs and two high-resolution ADCs (ADS1292 and ADS1292R) • Low power: 335 μW/channel • Input-referred noise: 8 μVPP (150-Hz BW, G = 6) • Input bias current: 200 pA • Data rate: 125 SPS to 8 kSPS • CMRR: 120 dB • Programmable gain: 1, 2, 3, 4, 6, 8, or 12 • Su

文件:2.36085 Mbytes 页数:83 Pages

TI

德州仪器

ADS1292IRSMR.A

丝印:ADS1292;Package:VQFN(RSM);ADS129x Low-Power, 2-Channel, 24-Bit Analog Front-End for Biopotential Measurements

1 Features 1• Two low-noise PGAs and two high-resolution ADCs (ADS1292 and ADS1292R) • Low power: 335 μW/channel • Input-referred noise: 8 μVPP (150-Hz BW, G = 6) • Input bias current: 200 pA • Data rate: 125 SPS to 8 kSPS • CMRR: 120 dB • Programmable gain: 1, 2, 3, 4, 6, 8, or 12 • Su

文件:2.36085 Mbytes 页数:83 Pages

TI

德州仪器

ADS1292IRSMR.B

丝印:ADS1292;Package:VQFN(RSM);ADS129x Low-Power, 2-Channel, 24-Bit Analog Front-End for Biopotential Measurements

1 Features 1• Two low-noise PGAs and two high-resolution ADCs (ADS1292 and ADS1292R) • Low power: 335 μW/channel • Input-referred noise: 8 μVPP (150-Hz BW, G = 6) • Input bias current: 200 pA • Data rate: 125 SPS to 8 kSPS • CMRR: 120 dB • Programmable gain: 1, 2, 3, 4, 6, 8, or 12 • Su

文件:2.36085 Mbytes 页数:83 Pages

TI

德州仪器

ADS1292IRSMRG4

丝印:ADS1292;Package:VQFN(RSM);ADS129x Low-Power, 2-Channel, 24-Bit Analog Front-End for Biopotential Measurements

1 Features 1• Two low-noise PGAs and two high-resolution ADCs (ADS1292 and ADS1292R) • Low power: 335 μW/channel • Input-referred noise: 8 μVPP (150-Hz BW, G = 6) • Input bias current: 200 pA • Data rate: 125 SPS to 8 kSPS • CMRR: 120 dB • Programmable gain: 1, 2, 3, 4, 6, 8, or 12 • Su

文件:2.36085 Mbytes 页数:83 Pages

TI

德州仪器

ADS1292IRSMRG4.A

丝印:ADS1292;Package:VQFN(RSM);ADS129x Low-Power, 2-Channel, 24-Bit Analog Front-End for Biopotential Measurements

1 Features 1• Two low-noise PGAs and two high-resolution ADCs (ADS1292 and ADS1292R) • Low power: 335 μW/channel • Input-referred noise: 8 μVPP (150-Hz BW, G = 6) • Input bias current: 200 pA • Data rate: 125 SPS to 8 kSPS • CMRR: 120 dB • Programmable gain: 1, 2, 3, 4, 6, 8, or 12 • Su

文件:2.36085 Mbytes 页数:83 Pages

TI

德州仪器

详细参数

  • 型号:

    ADS1292I

  • 制造商:

    TI

  • 制造商全称:

    Texas Instruments

  • 功能描述:

    Low-Power, 2-Channel, 24-Bit Analog Front-End for Biopotential Measurements

供应商型号品牌批号封装库存备注价格
TI
2016+
VQFN32
3000
只做原装,假一罚十,公司可开17%增值税发票!
询价
TI
24+
VQFN32
5000
全现原装公司现货
询价
TI
24+
TQFP32
44300
TI一级代理专营品牌绝对进口原装假一赔十
询价
TI
23+
TQFP32
8560
受权代理!全新原装现货特价热卖!
询价
TI
25+
TQFP32
8600
百分百原装正品 真实公司现货库存 本公司只做原装 可
询价
TI
三年内
1983
只做原装正品
询价
TI
19+
TQFP32
21300
原装正品,现货特价
询价
TI
16+
VQFN-32
10000
原装正品
询价
TI/德州仪器
20+
QFN
53650
TI原装主营-可开原型号增税票
询价
TI
20+
VQFN32
11520
特价全新原装公司现货
询价
更多ADS1292I供应商 更新时间2025-12-11 11:27:00